Description
Re-Injectable Grouting Hose
Kistube RI, in use together with Kensetsu grouting chemicals, provides a designed solution for water-tightness in new structures.
Kistube RI is installed and secured in place prior to concrete pour. This injectable grout system allows a variety of Kensetsu grouting chemicals to permanently seal voids, the interfaces within penetrations, construction joints, walls by a fast, simple and low-pressure grouting method. Grouting is to be carried out only after the concrete is cured till minimum shrinkage is expected thereafter.
Kistube RI is made with special slit, which will open when a low-pressure (>1 bar) is applied, and this design also prevent the infiltration of concrete water during casting. It is extremely flexible and is capable to follow contours and other construction designs. Placement are recommended to be in lengths of 10 metres, and in some cases, up to 30 metres if required.
![]() |
---|